IP Vandal Resistant Substation – 1008041100

IP Vandal Resistant Substation – 1008041100
IP Vandal Resistant Substation – 1008041100

Product Replaced by 1008041200 TKIE

For more information

If you seek professional advice on which product to select, don’t hesitate to contact RingUK’s specialists today. Our team will evaluate your requirements, research, and clarify all available options to assist you or your client in selecting the ideal system that satisfies your needs.

Contact us via our Enquiry Form.

“The 1008041100 IP Vandal Resistant Substation is tough, durable and resilient, and designed for use in the harshest of environments”

for use with AlphaCom , IC-Edge IP systems

Features

  • Compatible with AlphaCom, IC-Edge, Pulse and iPBXs (SIP)
  • Designed to deliver CCoIP® – Critical Communication over IP
  • Vandal and water resistant
  • Designed in stainless steel (A304) to withstand corrosion
  • Remote software upgrade, configuration and monitoring
  • Integrated data switch with advanced networking and security functions
  • Relay output for remote control, e.g. doors, signal lamps and gates
  • Powered from the IP network cable using Power over Ethernet (PoE)
  • Superb audio quality – high bandwidth codec, active noise cancellation, acoustic echo cancellation and high output power amplifier

IP Vandal Resistant Substation – 1008041100 Description

The Vandal Resistant IP Intercom Substation is tough, durable and resilient, and designed for use in the harshest of environments. The station is typically used as a communication, information or emergency point and connects directly to the IP network making it easy to deploy – anywhere and at any distance.

IP Standards

The IP station supports open standards and is compatible with AlphaCom, IC-Edge, Pulse and iPBXs using SIP technology. When working in AlphaCom mode, the IP station supports special services only available using the CCoIP protocol, AlphaCom server. Examples of services are emergency broadcast with volume override, CCTV integration, call priority, and AlphaNet multisite networking and event scripting.

Superb Audio Quality

Like all Vingtor-Stentofon stations, this IP substation features superb audio quality. This is enabled through a set of advanced technologies such as active noise filtering, acoustic echo cancellation, wide band audio codec, and high power audio outputs.

Connections

The station has one relay and one logical output. These outputs can, for instance, be used to open a door through a connected relay. The IP substation has an integrated managed data switch providing advanced networking and security features. The integrated switch provides support for:

  • Protection from unwanted access
  • Quality of Service (QoS) by managing data traffic
  • Increased system availability through redundant LAN infrastructure
  • Cost efficient installation by providing shared network connections

Supervision Functions

To provide maximum availability the station comes with advanced supervision functions. The station line test will detect if there is any faults in the network or station electronics. In addition the station supports tone test, testing the complete transmission path including microphone and speaker. The status of the stations is reported to AlphaWeb as well as to 3rd party management systems using SNMP, Syslog or OPC.


IP Vandal Resistant Substation – 1008041100 Specification

GENERAL
Dimensions (HxWxD)180 x 92 x 46 mm
Weight0.8 kg
ProtectionVandal resistant design, 2 mm stainless steel front, tamper proof loudspeaker grill, button and fastening screws
Protection classWith mounting box1008098000 (on wall): IP-44, With mounting box 1008098100 (flush mount): IP-55
Impact resistance ratingIK08
MountingFlush mount in 50 mm deep back box
Temperature-40˚C to +55˚C
Relative humidity0% – 95%
PowerPower over Ethernet, IEEE 802.3 a-f, Class 0 , Local power 19 – 27 VDC, Idle 4W, max. 8W
SPL rated power at 1m in open duplex85 dB
Connectors2 x RJ45 (Ethernet) 10/100 Mbps, Pluggable screw terminals (audio and IO)
Remote control3 digital inputs, 1 relay output and one logical output
Max. switching capacity30W DC
Max. voltage relay60V DC
Max current relay1A DC
SIPRFC 3261, SIP Info (DTMF), RFC 2833 (DTMF)
IP protocolsIP v4 – TCP – UDP – HTTPS – TFTP – RTP – RTCP -DHCP – SNMP -DiffServ – TOS – Vingtor-Stentofon CCoIP® – SIP
LAN protocolsPower over Ethernet (IEEE 802.3 a-f), VLAN (IEEE 802.1pq), Network Access Control (IEEE 802.1x), STP (IEEE 802.1d), RSTP (IEEE 802.1d-2004)
Audio technologyWideband 200 Hz – 7 kHz (G.722) , Telephony 3.4kHz (G.711), Active noise filtering , Acoustic echo cancellation, Open duplex, Adaptive jitter filter, 1.5 Watt audio output, 8 ohm loudspeaker impedance, External audio out (0dB, 600 ohm)
Management and operationHTTPS (Web configuration), DHCP and static IP , Remote automatic software upgrade, Centralized monitoring, Status LED
Advanced featuresDual port managed data switch supporting VLAN and network access control
ComplianceCE and FCC Part 15

IP Vandal Resistant Substation – 1008041100 Dimensions

IP Vandal Resistant Substation – 1008041100 Dimensions

IP Vandal Resistant Substation – 1008041100 Accessories

On Wall Back Box 1008098000
On Wall Back Box 1008098000
Flush Mount Back Box 1008098100
Flush Mount Back Box 1008098100
Surface Back Box with Hood 1008098-H
Surface Back Box with Hood 1008098-H

Door Station Range

Web PagePart Number:Replaced By:
IP Single Button Vandal Resistant Substation1008041100TKIE
IP Single Button Vandal Resistant SubstationTKIE1008041200
Back Boxes
Flush Mount Back Box for IP Vandel Resistant Substation – TKIE – 10080981001008098100
On Wall Back Box for IP Vandel Resistant Substation – TKIE – 10080980001008098000

Intercom Station Range

Description
Cleanroom & Operating Theatre
Control Room
Desk or Wall
Door
Heavy Duty Telephone
Turbine
Vandal and Tamper
IP, VoIP & SIP Station Range
Video and Touch Screen
Station Accessories

For more information

If you seek professional advice on which product to select, don’t hesitate to contact RingUK’s specialists today. Our team will evaluate your requirements, research, and clarify all available options to assist you or your client in selecting the ideal system that satisfies your needs.

Contact us via our Enquiry Form.