For more information
If you seek professional advice on which product to select, don’t hesitate to contact RingUK’s specialists today. Our team will evaluate your requirements, research, and clarify all available options to assist you or your client in selecting the ideal system that satisfies your needs.
Contact us via our Enquiry Form.
Description
- One single-paired cable can be used to distribute power and data network
- Switch to toggle between PoE forwarding on and off
- The cable hauls can be longer, reducing the need for switches and/or repeaters
- Up to 9 Flowire devices can be connected to the same 2-wire network structure
- Existing two-wire infrastructure can be used reducing the total cost of retrofit projects
- The Flowire Converter can be used with any Ethernet enabled device
The FCDC3 Flowire Converter enables Ethernet to run on the same two wires as power, providing simpler cabling and opens up for longer cable hauls. The Flowire Converter is also capable of powering Ethernet devices attached to it, such as IP intercom stations and CCTV cameras.
Specifications
MECHANICAL | |
Dimensions | 107 x 74 x 26 mm |
Weight | 300 g |
Mounting | Wall mount or DIN rail |
IP rating | IP 20 |
ENVIRONMENTAL | |
Operating temperature | -40°C to +70°C |
Operating humidity | 15% to 95% (non-condensing) |
Storage temperature | -40°C to + 70°C |
Storage humidity | 10% to 95% (non-condensing) |
NETWORK | |
Flowire | Up to 400 Mbps @ 100m *), Up to 200 Mbps @ 500m *), *) Tested under typical conditions. Available bandwidth depends on cable type, cable length and number of attached devices. Total cable length for a Flowire cluster should not exceed 600 m. |
ELECTRICAL | |
Nominal voltage | V NOM = 24VDC – 48VDC, V MIN = 18VDC, V MAX = 56VDC |
Power consumption | P NOM = 2.5W, P MAX = 6W |
Power forwarding, compatible with PoE Mode B (Spare pair) | P MAX = 15W |
Note | Max power feed to a Flowire cluster is 3A. If the power supply can deliver more, an external fuse is recommended. |
ELECTROMAGNETIC COMPATIBILITY (EMC) | |
Immunity | IEC/EN 60945:2002/Cor1:2008, EN 61000-6-2:2005 |
Emissions | IEC/EN 60945:2002/Cor1:2008, EN 61000-6-3:2007+A1:2011 |
Dimensions
Turbine Intercom Station Range
For more information
If you seek professional advice on which product to select, don’t hesitate to contact RingUK’s specialists today. Our team will evaluate your requirements, research, and clarify all available options to assist you or your client in selecting the ideal system that satisfies your needs.