16 Port Gigabit Layer 2 Managed Industrial Ethernet Switch |
Sixteen 10/100/1000BaseT RJ-45 Ports |
Hardware Features |
Compact, space saving, hardened industrial design |
Wide operating temperature |
High shock and vibration tolerance |
– Vibration: 5Hz to 200Hz, 15g, Triaxial; IEC 68-2-6: operational; bulkhead mounted |
– Shock: 200g, 10ms, Triaxial; IEC 68-2-27: non-operational; bulkhead mounted |
Reverse polarity protection |
ESD and Surge protection |
Fast boot <20 seconds |
Configurable Alarm Contact |
Configurable Bi-Colour Fault Status LED |
LED port status indicators |
Jumbo frame support |
Redundant Power Inputs (10-49 VDC) |
Management Features |
Modern, intuitive Web Interface |
– Configuration wizard |
– Graphical dashboard and logical view of the switch |
Command Line Interface |
Port Control |
IGMP v1/v2/v3 auto-configuration |
SNMP v1/v2/v3 |
NTP |
802.1Q tag VLAN and Port VLAN |
IEEE 802.1p QoS and Port QoS |
DHCP Client |
Text-based configuration file |
File transfer: HTTP/HTTPS, TFTP, SNMP |
Security Features |
SSH, SSL, HTTPS |
MAC Filtering |
IEEE 802.1x with RADIUS remote server authentication |
Port / User lock after failed authentication attempts |
SNMPv3 |
Password encryption |
Diagnostic Features |
Port mirroring |
Event log/Syslog |
LLDP |
Advanced cable diagnostics |
Network Redundancy Features |
RSTP/MSTP |
Port trunking / LACP |
N-Ring auto-member |
Software tool to manage/schedule firmware upgrades |
N-View™ 2 |
Regulatory Certifications |
Product Safety: (UL/CUL) Ordinary and Hazardous locations |
Emissions/Immunity: FCC/ICES/CE |
ATEX/IECEx |
Marine: ABS, DNV (pending) |
Rail: EN 50155, EN 50121, EN 61373 |
Ordering Guide
Main Unit
PART NUMBER | DESCRIPTION |
---|---|
NT-5018-DM2-0000 | 18-Port Gigabit Managed Industrial Ethernet Switch (16 10/100/1000BaseT RJ45 Ports, 2 Dual Mode 100/1000Base SFP Expansion Slots) |
Accessories
PART NUMBER | DESCRIPTION |
---|---|
NT-CPMA-03-00000 | NT5000 Panel Mount Kit, Type A (Wide) |
NTPS-24-1-3 | DIN Rail Power Supply, 1.3 Amp @ 24 VDC |
NTSFP-FX | 100BaseFX Multimode Fiber SFP Transceiver (LC Style Connector, 2 km) |
NTSFP-FXE-15 | 100BaseFX Singlemode Fiber SFP Transceiver (LC Style Connector, 15km) |
NTSFP-FXE-40 | 100BaseFX Singlemode Fiber SFP Transceiver (LC Style Connector, 40 km) |
Ordering Guide
Main Unit
PART NUMBER | DESCRIPTION |
---|---|
NT-5016-000-0000 | 16-Port Gigabit Managed Industrial Ethernet Switch (16 10/100/1000BaseT RJ45 Ports) |
Accessories
PART NUMBER | DESCRIPTION |
---|---|
NT-CPMA-03-00000 | NT5000 Panel Mount Kit, Type A (Wide) |
NTPS-24-1-3 | DIN Rail Power Supply, 1.3 Amp @ 24 VDC |
Dimensions
nt5016-dimension-drawingBrochure
nt5000-brochure_2NT5000 Downloads
PRODUCT MANUAL |
NT5000 Series Hardware Manual |
QUICK START GUIDE |
NT5000 Quick Start Guide |
BROCHURE |
NT5000 Brochure |
Datasheet |
N-View™ 2 Data Sheet |
SOFTWARE MANUAL |
N-View™ 2 Software Manual |
NT5000 Software Manual |
NT5000 Switch Range
Part # | Total Ports | 10/100/1000 | 100 Fiber | Gig Fiber | SFP | Operating Temp | IP Rating | Mounting | Fiber Connector | Fiber Type | Fiber Distance Rating |
---|---|---|---|---|---|---|---|---|---|---|---|
NT-5006-000-0000 | 6 | 6 | – | – | – | -40˚ to 85˚C | – | DIN-Rail | – | – | – |
NT5006-DM2-0000 | 6 | 4 | – | – | 2 | -40˚ to 85˚C | – | DIN-Rail | Multimode/Singlemode | LC | 2 km & 15km |
NT5008-000-0000 | 8 | 8 | – | – | – | -40˚ to 85˚C | – | DIN-Rail | – | – | – |
NT5008-DM2-0000 | 8 | 6 | – | – | 2 | -40˚ to 85˚C | – | DIN-Rail | Multimode/Singlemode | LC | 2km/15km & 40km |
NT-5008-FX2 Range | 8 | 6 | 2 | – | – | -40˚ to 85˚C | – | DIN-Rail | More Info | – | – |
NT5008-GX2 Range | 8 | 6 | – | 2 | – | -40˚ to 85˚C | – | DIN-Rail | More Info | – | – |
NT5010-DM2-0000 | 10 | 8 | – | – | 2 | -40˚ to 85˚C | – | DIN-Rail | Multimode/Singlemode | LC | 2km/15km 40km & 80km |
NT5010-FX2 Range | 10 | 8 | 2 | – | – | -40˚ to 85˚C | – | DIN-Rail | More Info | – | – |
NT5010-GX2 | 10 | 8 | 2 | – | -40˚ to 85˚C | – | DIN-Rail | More Info | – | – | |
NT5016-000-0000 | 16 | 16 | – | – | – | -40˚ to 80˚C | – | DIN-Rail | – | – | – |
NT5018-DM2-0000 | 18 | 16 | – | – | 2 | -40˚ to 80˚C | – | DIN-Rail | Multimode/Singlemode | LC | 2km/15km & 40km |
NT5018-FX2 Range | 18 | 16 | – | 2 | – | -40˚ to 80˚C | – | DIN-Rail | More Info | – | – |
NT5018-GX2 Range | 18 | 16 | – | 2 | – | -40˚ to 80˚C | – | DIN-Rail | More Info | – | – |
For more information
If you seek professional advice on which product to select, don’t hesitate to contact RingUK’s specialists today. Our team will evaluate your requirements, research, and clarify all available options to assist you or your client in selecting the ideal system that satisfies your needs.