“A PICU Seclusion Room Intercom system between the patient in the seclusion room and the staff in the corridor is provided via a Ant-Ligature speaker and microphone mounted in the ceiling of the seclusion room and an Intercom Panel in the Corridor”
Features:
- Hands-Free Communications
- Ceiling Mounted Microphone & Anti-Ligature Speaker
- Forced One-way Communication
- En-Suite Water Resistant Ant-ligature Speaker and Microphone (Option)
- Remote Music Input (Option)
- The remote Intercom station can be fitted at Nurse Base.(Option)
- Telephone Panel to provide communications to family etc. (Option)
PICU Seclusion Room Intercom
Enhance Communication and Safety in the PICU Seclusion Room
Effective communication between patients in the PICU seclusion room and staff in the corridor is essential for safety and care. Our intercom system is designed with anti-ligature features to ensure security and reliability while complying with regulatory guidelines.
Key Features:
- Anti-Ligature Design
The system includes a ceiling-mounted speaker and microphone in the seclusion room, paired with a durable intercom station in the corridor. Available in flush-mounted stainless steel as standard, with surface-mounted options upon request. - Regulatory Compliance
Aligned with the Mental Health Act (MHA) Code of Practice, the system allows seamless communication when the seclusion room door is locked:
“Allow for communication with the patient when the patient is in the room, and the door is locked, for example, via an intercom.” - Two-Way Communication
The corridor intercom station enables staff to listen to the patient and respond as needed. A simple “Press to Talk” button allows clear and direct communication. - Optional Enhancements
- En-Suite Integration: An additional water-resistant microphone and speaker can be installed for extended functionality.
- Music Playback: An optional music feature is available, with a K2Audio unit supporting Bluetooth and 3mm mini-jack input.
- Proven Reliability
With over 200 systems installed in hospitals across the UK, our intercom solutions are trusted by healthcare providers nationwide.
Why Choose Us?
Our intercom systems combine robust design with advanced features, ensuring safety, compliance, and ease of use. Whether you need a standard system or enhanced options like en-suite integration or music playback, we provide solutions tailored to your needs.
Contact us today to learn more about our PICU Seclusion Room Intercom systems and how we can support your facility.
PICU Seclusion Room Intercom Installation
- Corridor Station should be mounted for easy operator access, and this is flush-mounted. (surface mount can be supplied at special request)
- We recommend the System Control Box is mounted outside of the room above. The ceiling in the Corridor is recommended for future access if adjustments are required.
- The cable between the Corridor station and the Control box is a CAT5E/6 cable
- Mains power is required for the System Control Box.
- The cable for the microphone should be screened microphone cable 31-059 CANFORD FST-LFH CABLE or equivalent
- The speaker requires 2 core speaker cable 224-GY West Penn Wire or equivalent
PICU Seclusion Room Intercom Operation
- To Communicate with the room, press the top button. This will open one-way listening to the room communications.
- Use the middle button to talk to the room. Press and hold the middle button for one-way communication. Let go of the middle button to return to listen mode.
- To cancel all communications (Switch OFF), press the bottom button.
Seclusion Room Intercom Datasheets
Installing the Microphone Installing the Microphone, Pre-New Microphone January/February 2024 |
KLABXBG2F are Used when an Audio Music input is required. Feed via a 3.5mm Mini Jack connection or Bluetooth. |
Installing the Microphone Installing the Microphone, Pre-New Microphone January/February 2024 |
Microphone Mounted in the Ceiling of Seclusion Room after January/February 2024 |
Corridor Panel Drawing Corridor Front Panel Drawing Showing Sizes, etc |
Installing the Microphone Installing the Microphone with the New Microphone, January/February 2024 |
Microphone Connects Connections inside System Control Box for Microphone |
Corridor Station IP Vandal Resistant Substation TKIE – 1008041200 Standard Station without Special Front Panel |
Flush Mount Back Box for IP Vandel Resistant Substation – TKIE – 1008098100 |
Corridor Panel Drawing Corridor Front Panel Drawing Showing Sizes etc |
System Control Box Picture of the System Control Box that should be Mounted Where Access can be made for Maintenance |
Control Station VoIP Intercom Module TKIS-2 – 1008131020 Mounted Inside the System Control Box |
SIP Phone Panel Option |
Seclusion Room Intercom System Drawings
Seclusion Room Intercom System with Music
Seclusion Room Intercom System with Music – New Microphone January/February 2024
Seclusion Room Intercom System with En-Suite and Music
Seclusion Room Intercom System with En-Suite and Music – New Microphone January/February 2024
Security Intercom Market
Intercom Markets
For more information
If you seek professional advice on which product to select, don’t hesitate to contact RingUK’s specialists today. Our team will evaluate your requirements, research, and clarify all available options to assist you or your client in selecting the ideal system that satisfies your needs.