“Catheter Lab to Control room Intercom to provides Communications between the Operator in the Catheter Lab and the control room, communications is provided via a speaker mounted in the Lab ceiling and a directional microphone mounted on the Monitor stack”
A Catheter Lab to Control room Intercom Can:
- Talk back to Control Room When Required
- Music if required (Option)
Catheter Lab to Control Room Intercom Description
The Catheter Lab to Control Room Intercom is a critical component of any modern healthcare facility, providing seamless communication between the operator in the catheter lab and the control room staff. The intercom system is designed to ensure that essential information is relayed in real-time, allowing for quick and effective decision-making, which can ultimately improve patient outcomes.
The intercom system comprises a speaker mounted in the ceiling, which delivers clear and crisp audio, even in noisy environments. The directional microphone, which is mounted on the monitor stack, ensures that the operator’s voice is transmitted clearly and precisely, regardless of their location in the lab.
One of the key benefits of the intercom system is its ability to enhance collaboration between the operator in the catheter lab and the control room staff. The system enables the operator to receive critical information from the control room, such as patient vital signs while providing an avenue for the operator to communicate any changes or updates in the procedure to the control room.
The intercom system is also essential for ensuring that any emergencies or unexpected events in the lab can be dealt with quickly and efficiently. In such situations, the operator can alert the control room staff using the intercom, and appropriate actions can be taken to address the issue promptly.
In summary, the Catheter Lab to Control Room Intercom system is an indispensable tool for any healthcare facility that values effective communication, collaboration, and patient safety. With its high-quality audio and directional microphone, the intercom system facilitates efficient communication between the catheter lab and the control room, improving patient outcomes and ensuring a safe and effective working environment for healthcare professionals.
Intercom Operation
To communicate with the lab, press the “Call” key, this will open the communication system in Listen only mode then press and hold the “PTT” key to talk to the lab, let go to return to listen mode
Staff in the lab cannot hear the operator without the “PTT” key being pressed
When Pressing the “PTT” key the relay will cut music from Avid if fitted
Close System
To cancel all communications (Switch OFF) press “Close”
Installation
- The control room station should be mounted for easy operator access.
- The system control box should be mounted in the control room.
- The cable between the Control room station and the control box is a CAT5/6 cable
- Power is required at the System control box
- The cable for microphone should be screened microphone cable 31-059 CANFORD FST-LFH CABLE 1 pair Black or equivalent
- The speaker requires 2 core speaker cable Speaker Cable 224-GY West Penn Wire or equivalent
Sample System
proposal-cath-lab-to-control-room-intercom-system-with-music-optionPictures
Datasheets
Installing the Microphone Installing the Microphone, Pre-New Microphone January/February 2024 |
KLABXBG2F are Used when an Audio Music input is required. Feed via a 3.5mm Mini Jack connection or Bluetooth. |
Installing the Microphone Installing the Microphone, Pre-New Microphone January/February 2024 |
Microphone Mounted in the Ceiling of Seclusion Room after January/February 2024 |
Corridor Panel Drawing Corridor Front Panel Drawing Showing Sizes, etc |
Installing the Microphone Installing the Microphone with the New Microphone, January/February 2024 |
Microphone Connects Connections inside System Control Box for Microphone |
Corridor Station IP Vandal Resistant Substation TKIE – 1008041200 Standard Station without Special Front Panel |
Flush Mount Back Box for IP Vandel Resistant Substation – TKIE – 1008098100 |
Corridor Panel Drawing Corridor Front Panel Drawing Showing Sizes etc |
System Control Box Picture of the System Control Box that should be Mounted Where Access can be made for Maintenance |
Control Station VoIP Intercom Module TKIS-2 – 1008131020 Mounted Inside the System Control Box |